Controlled Power Outdoor UPS Systems
Controlled Power outdoor-ups PDF Print E-mail
Model LTN

Uninterruptible Power System
Designed to be used with linear or non-linear load applications.

Controlled Power Company engineers and manufactures the industry’s highest quality uninterruptible power systems, capitalizing on 3 decades of expertise. We have an enviable reputation for quality, which is reflected in the design, workmanship, and performance
of our products.

Applications:
• Indoor / Outdoor Security Systems
• Security Cameras / Surveillance Networks
• Parking Structures / Garages / Tollgates
• Traffic Signals
• Mass Transit
• Industrial / Automated Process Control
• Pump Stations
• Water Treatment Facilities
• Irrigation Systems
• Transmission Repeaters
• Supervisory Control and Data Acquisition (SCADA)
• Telecommunications
• Cell-Phone Towers

Features & Benefits
• Uninterrupted, regulated, continuous sinewave output
• Integral constant voltage transformer isolates and regulates output voltage
• Integral status and alarm panel
• Remote communications via alarm signals or RS232
• Integral battery options — consult factory for specific runtimes
• Front-access design
• Wall or floor-mounted options — consult factory
• NEMA 2 enclosure (standard).
• Optional outdoor-rated NEMA 3R enclosure. Powder-coated, UV-rated paint is standard. Stainless steel enclosure is optional – consult factory.
• Optional output circuit breakers, remote status panel, accelerated battery charger, and automatic phone dialer.
• Generator-compatible

Standards
• UL / cUL 1778
• NFPA 70 National Electric Code
• ANSI / IEEE C62.41 Category B3
• FCC Article 15, J, Class A

Bright, 3-Digit LED Provides System Parameters:
• Input voltage
• Percent of battery capacity
• Output voltage
• Percent of battery charged
• Percent of load

LED Indicators Provide System Status:
• System ON (Green)
• LOW BATTERY Warning (Red)
• System ON BATTERY (Yellow)
• ALARM (Red)

Product Specifications
• Input Operating Voltage Range: +10%, – 40% typical, load-dependent, without battery usage
• Input Frequency: 60 Hz, ± 2.5%
• Output Sine Wave Voltage: Maximum 3% harmonic distortion, any single harmonic
• Load Regulation: Typically better than ± 3%
• Output Line Voltage Regulation: Typically better than ± 3%
• Isolation: Galvanic
• Standard Unit Operating Temperature: 0º C to +40º C
• Outdoor-rated Unit Operating Temperature: –35º C to +55º C
• Total System MTBF: 100,000 hours
• Common Mode: 120 dB
• Transverse Mode: 70 dB
• Efficiency 89%

LTN Model Numbers
ModelsWattsInput VAC 60 Hz Output VAC 60 Hz Battery Runtimes (Full/Half load) BTU's / Hour Weight (lbs)*
LTN700500120, 208, 240120, 120/208, 120/24022.5m / 1h thru 7h / 14h256223
LTN850600120, 208, 240120, 120/208, 120/24018m / 48m thru 5h 30m / 10h 30m307223
LTN1000700120, 208, 240120, 120/208, 120/24013m / 30m thru 3h 48m / 7h 55m359238
LTN1200850120, 208, 240120, 120/208, 120/24012m / 27m thru 3h 36m / 7h435257
LTN14001000120, 208, 240120, 120/208, 120/2408m / 23m thru 2h 49m / 5h 50m512257
LTN16001200120, 208, 240120, 120/208, 120/2407m / 17.5m thru 2h 26m / 5h 7m614257
LTN18001300120, 208, 240120, 120/208, 120/2409.5m / 26m thru 2h 18m / 4h665267
LTN21001500120, 208, 240120, 120/208, 120/2407.5m / 21.5m thru 2h 5m / 3h 47m767267

*Cabinet weight only; does not include weight of batteries. Battery weights vary according to desired runtimes.
Battery runtimes: m = minutes, and h = hours. Dependent on battery option purchased. Battery runtimes stated above reflect
standard minimum and maximum options. Consult factory.
Product dimensions are 39" H x 31" W x 16.6" D.