Model LTN  | Uninterruptible Power System Designed to be used with linear or non-linear load applications. Controlled Power Company engineers and manufactures the industry’s highest quality uninterruptible power systems, capitalizing on 3 decades of expertise. We have an enviable reputation for quality, which is reflected in the design, workmanship, and performance of our products.
| Applications: • Indoor / Outdoor Security Systems • Security Cameras / Surveillance Networks • Parking Structures / Garages / Tollgates • Traffic Signals • Mass Transit • Industrial / Automated Process Control • Pump Stations • Water Treatment Facilities • Irrigation Systems • Transmission Repeaters • Supervisory Control and Data Acquisition (SCADA) • Telecommunications • Cell-Phone Towers Features & Benefits • Uninterrupted, regulated, continuous sinewave output • Integral constant voltage transformer isolates and regulates output voltage • Integral status and alarm panel • Remote communications via alarm signals or RS232 • Integral battery options — consult factory for specific runtimes • Front-access design • Wall or floor-mounted options — consult factory • NEMA 2 enclosure (standard). • Optional outdoor-rated NEMA 3R enclosure. Powder-coated, UV-rated paint is standard. Stainless steel enclosure is optional – consult factory. • Optional output circuit breakers, remote status panel, accelerated battery charger, and automatic phone dialer. • Generator-compatible | Standards • UL / cUL 1778 • NFPA 70 National Electric Code • ANSI / IEEE C62.41 Category B3 • FCC Article 15, J, Class A Bright, 3-Digit LED Provides System Parameters: • Input voltage • Percent of battery capacity • Output voltage • Percent of battery charged • Percent of load LED Indicators Provide System Status: • System ON (Green) • LOW BATTERY Warning (Red) • System ON BATTERY (Yellow) • ALARM (Red) | Product Specifications • Input Operating Voltage Range: +10%, – 40% typical, load-dependent, without battery usage • Input Frequency: 60 Hz, ± 2.5% • Output Sine Wave Voltage: Maximum 3% harmonic distortion, any single harmonic • Load Regulation: Typically better than ± 3% • Output Line Voltage Regulation: Typically better than ± 3% • Isolation: Galvanic • Standard Unit Operating Temperature: 0º C to +40º C • Outdoor-rated Unit Operating Temperature: –35º C to +55º C • Total System MTBF: 100,000 hours • Common Mode: 120 dB • Transverse Mode: 70 dB • Efficiency 89%
|
| LTN Model Numbers |  | | Models | Watts | Input VAC 60 Hz | Output VAC 60 Hz | Battery Runtimes (Full/Half load) | BTU's / Hour | Weight (lbs)* |  | | LTN700 | 500 | 120, 208, 240 | 120, 120/208, 120/240 | 22.5m / 1h thru 7h / 14h | 256 | 223 |  | | LTN850 | 600 | 120, 208, 240 | 120, 120/208, 120/240 | 18m / 48m thru 5h 30m / 10h 30m | 307 | 223 |  | | LTN1000 | 700 | 120, 208, 240 | 120, 120/208, 120/240 | 13m / 30m thru 3h 48m / 7h 55m | 359 | 238 |  | | LTN1200 | 850 | 120, 208, 240 | 120, 120/208, 120/240 | 12m / 27m thru 3h 36m / 7h | 435 | 257 |  | | LTN1400 | 1000 | 120, 208, 240 | 120, 120/208, 120/240 | 8m / 23m thru 2h 49m / 5h 50m | 512 | 257 |  | | LTN1600 | 1200 | 120, 208, 240 | 120, 120/208, 120/240 | 7m / 17.5m thru 2h 26m / 5h 7m | 614 | 257 |  | | LTN1800 | 1300 | 120, 208, 240 | 120, 120/208, 120/240 | 9.5m / 26m thru 2h 18m / 4h | 665 | 267 |  | | LTN2100 | 1500 | 120, 208, 240 | 120, 120/208, 120/240 | 7.5m / 21.5m thru 2h 5m / 3h 47m | 767 | 267 |
*Cabinet weight only; does not include weight of batteries. Battery weights vary according to desired runtimes. Battery runtimes: m = minutes, and h = hours. Dependent on battery option purchased. Battery runtimes stated above reflect standard minimum and maximum options. Consult factory. Product dimensions are 39" H x 31" W x 16.6" D.
|